Log in
For Calscan Hawk and Crystal nVision recorders

The chart you trust, without the paper.

Upload the file from your pressure recorder and get a strip chart or Barton-style round chart, the hold worked out and a client-ready PDF. Nothing to install, and every test stays on file and searchable.

Free for 15 uploads a year. Unlimited users. No account needed to try it.

Strip and Barton charts from the same readings

Every channel the recorder logged, on one time line. Zoom from the whole test down to a single reading, and the hold is worked out for you.

Round charts, without the chart recorder

Many clients and regulators still expect a round chart. TestVault draws it from the recorder's own readings on familiar green-grid paper, with no pens, ink or chart stock.

  • 24 hour, 7 day and 8 day charts, lined up on the hour
  • Meter, put on, taken off, location and remarks filled in for you
  • Each channel its own pen colour
  • Prints to PDF with a QR code back to the chart

Drop the file. That's the whole job.

No converting and nothing to type. TestVault reads what it needs from the file and its name.

1

Download from the recorder

Pull the .BIN off the Hawk's SD card, or export the run from CrystalControl, same as you do now.

2

Drop the files in

One file or a day's worth. Serial, customer, start time and every channel come straight out of the file.

3

It's on file

Two tests in one file become two charts. Search later by customer, job, well, UWI, LSD or serial.

Calscan Hawk 9000 pressure recorder
Hawk photo courtesy of Calscan.

Works with the recorders you run

The recorder already logs good, stable data. The trouble is what happens to the file after: it ends up on somebody's laptop, a USB stick or an email from three months ago. TestVault gives every download one home.

Calscan Hawk9000 and 9500 .BIN files, as they come off the recorder
Crystal nVisionCrystalControl Data Collection Report .xlsx exports, modules and calibration dates included
ChannelsStatic and differential pressure, RTD temperature, every logged channel
Sample rateEvery reading kept, down to one second
Original fileKept exactly as uploaded, ready to download again

Name your channels once (casing, tubing, temp) and TestVault remembers them for that recorder's serial number.

Hand over a finished test package

One click for the report your customer, inspector or engineer needs.

  • PDF report: job details, strip or Barton chart, the hold with change and %, notes and test photos
  • CSV: every reading, one column per channel, plus your notes
  • Original file: the .BIN or export exactly as uploaded
  • Share link: customers open it on any device with no account. Links expire, and every view is logged
  • QR code on the PDF that opens the chart online

Still running paper charts?

Paper Barton charts have recorded pressure tests for decades, and your crew knows how to read them. Nothing has to change on day one: keep the round chart in the job file and let the numbers make the case.

Exact numbers
Instead of reading a pen line against the grid, you get the pressure at the start and end of the hold, the change and the change as a percentage.
Nothing fades or goes missing
No wet, faded or lost charts. Every test is kept with its original file and found again in seconds.
Same day to the customer
Send a link instead of scanning a chart and emailing it.
Run both side by side
Put the paper chart and the printed Barton chart next to each other for a few jobs. They should tell the same story.
Paper vs digital, compared
What changes, and what doesn't, when you go digital

Field photos, on the right chart

Deadweight steps, gauge readings and the setup, placed on the chart at the moment they were taken.

  • Text the crew a photo link, or let them scan the QR code on the recorder. No account needed.
  • Photos can arrive before the recorder file. They find their chart when it's uploaded.
  • Photo pages at the end of the PDF, and on the share page if you allow it.

Built for the tests you run

If your recorder logged it, TestVault can chart it, report it and find it again later.

Hydro tests & MIT
Mark the start and end of the hold right on the chart. It works out the hold time and how much pressure you gained or lost, then prints it all on the PDF for the inspector.
Pipeline pressure tests
Line segment, test pressure and the hold on one page, with the recorder's calibration status on the test date.
DFIT & offset monitoring
See the full one-second falloff, zoom right into shut-in, and send the engineer every reading as a CSV.
Build-ups
Two-week files open fast. Stack pressure and temperature, zoom to any day, find it again by well or LSD.
Flow & injectivity tests
Static, DP, temperature and turbine rates on the same time line, overlaid or stacked.

Questions

Something not covered here? Reply to any TestVault email.

What files does TestVault open?

.BIN files from Calscan Hawk 9000 and 9500 recorders, as they are, and Data Collection Report exports (.xlsx) from Crystal nVision recorders saved in CrystalControl. Every channel comes in, with the recorder serial, start time and interval, even when one file has more than one test in it.

Can I still print a round chart?

Yes. Every test can be printed as a Barton-style round chart (24 hour, 7 day or 8 day) or a strip chart, on a letter-size PDF, drawn from the same readings.

What about hydro tests and MITs?

TestVault finds the hold, or you click where it started and ended. It shades the hold on the chart, works out the time and the pressure change, and prints it on the PDF. It shows the numbers; pass or fail stays with you.

Does it work for DFIT data?

Yes. You get the full one-second falloff to zoom into and print, and a CSV of every reading for the engineer's analysis.

Is TestVault a CalWin alternative?

For viewing, printing, storing and sharing Hawk charts, yes. Keep using CalWin to program your Hawks; TestVault never changes recorder settings.

Is TestVault made by Calscan or Crystal?

No. TestVault is an independent product. It reads their file formats but is not affiliated with, endorsed by or sponsored by Calscan or Crystal Engineering.

Who can see my charts?

Only people in your company account. A customer only sees a chart if you send them a share link, which expires after 30 days by default, and every view is logged.

Can I delete my charts?

Yes. Deleted charts go to a recycle bin for 30 days, then they're removed for good along with their readings and the original file.

What does it cost?

Free for 15 uploads per company every 12 months. Pro is $99 CAD a year per company, plus GST/HST, for unlimited uploads. Both plans include unlimited users.

Have a recorder file handy?

Open it now and print the chart in under a minute. No account needed.

Try it with your file